Now you really can free yourself from cigarettes and take control of your health!
For medical professional use only. This product cannot be purchased for personal or home use.
The
Smokerlyzer System consists of a Personal Carbon
Monoxide Tester and a comprehensive quitting
plan which contains all the information the
smoker needs to stop smoking permanently.
Battery powered and easy to use, the Smokerlyzer®
Personal Tester measures the amount of carbon
monoxide (CO), a toxic gas, in the blood.
Features:
(1) Based on a clinical measuring system used by health professionals in Stop Smoking Clinics
(2) Simple to use and interpret
(3) Battery powered
(4) 1 year typical life even with heavy use
|
|
|
|
|
|
|
|
|
 |
|
|
How it works
The end of the
TobacAlert™ strip contains gold particles
coated with an antibody that selectively binds to cotinine in the urine. After the end of
the strip is dipped in urine, the gold particles migrate through specialized
“traps” in the strip. The more cotinine bound to a gold particle, the further it
is able to migrate along the strip. The reddish bands seen on the developed strip
correspond to gold particles caught in a particular trap.
TobacAlert™
is extremely sensitive and can measure amounts as low as 6 nanograms of cotinine per
milliliter of urine (6 billionths of a gram in one fifth of a teaspoon).
Urine Test Kit
The urine test kit contains a test strip, a detailed product insert and a plasticized card. The card outlines simple instructions and provides a non-absorbent surface to lay the strip on while performing the test.
Urine does not need to be processed, nor does it need to be "first morning" or "mid-stream". It does need to be clear and at room temperature. The tip of the test strip is dipped (not beyond the arrows), for 20 seconds and ten placed on the area indicated on the plastic card. After 15-20 minutes when the blue line at the strip's top disappears the test can be read.
Saliva Test Kit
The saliva test kit contains a test strip, a small funnel, a collection tube and a specialized filter cap.
Saliva is spit through the funnel into the tube. The filter cap is placed on the tube and the tube is squeezed until 8 drops have been placed on the end of the strip (indicated by arrows). The strip is then laid on a non-absorbent surface to develop for about 15 to 30 minutes.
It is important to recognize that it is the same test strip for both applications. What differs is the nature of the fluid being tested.
We can only sell to Medical Professionals
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|