Vacuette Tube
Sort By:
VACUETTE® Blood Collection Tubes; Additive: K2E K2EDTA; Volume: 4mL: Size: 13 x 75mm; Cap Style: Safety; Cap Color: Lavender; Ring Color: Black; Tube Type: Non-Ridged; Sterility: Sterile; Quantity: 50/Rack

  • VACUETTE® tubes are used to collect, transport and process blood for testing serum, plasma or whole blood in the clinical laboratory
  • Interior of the tube wall is coated with either K2EDTA or K3EDTA
  • EDTA binds calcium ions and blocks the coagulation cascade
  • VACUETTE® EDTA Tubes can be used in the closed mode with direct sampling analyzers
  • For parameter stability information, i.e., whole blood count (CBC) and differential (DIFF), follow the recommendations of the assay and/or instrument manufacturer. Refer to specific CLSI documents (i.e., guidelines, standards) for additional information.
  • VACUETTE® K3EDTA and K2EDTA Tubes may be used for routine immunohematology testing, i.e., red cell grouping, Rh typing and antibody screening
  • VACUETTE® K2EDTA and VACUETTE® K3EDTA Tubes may be used for viral marker testing in screening and clinical laboratories
  • VACUETTE® K3EDTA and K2EDTA Tubes are used for testing plasma in molecular diagnostics. The performance characteristics of this device have not been established for molecular diagnostics in general. Users must validate use of product for their specific molecular diagnostic assay. VACUETTE® K2EDTA with Gel Tubes are used for testing plasma in molecular diagnostics.
Greiner Bio-One VACUETTEŽ Blood Collection Tubes, 4mL, K2E K2EDTA, 13 x 75mm, Lavender Safety Cap, Black Ring, Non-Ridged, Sterile (50/Rack)  [ MS0101-4542009 ]
Price: $9.99
Quantity:
  
VACUETTE® Blood Collection Tubes; Additive: 9NC Coagulation Sodium Citrate 3.2%; Volume: 3mL: Size: 13 x 75mm; Cap Style: Safety; Cap Color: Blue; Ring Color: Black; Tube Type: Sandwich, Non-Ridged; Sterility: Sterile; Quantity: 50/Rack

  • VACUETTE® tubes are used to collect, transport and process blood for testing serum, plasma or whole blood in the clinical laboratory
  • VACUETTE® Coagulation Tubes are filled with buffered tri-sodium citrate solution
  • Citrate concentration is 0.109M (3.2%)
  • Mixing ratio is 1 part citrate to 9 parts blood
  • High Altitude 3.2% sodium citrate tubes with increased vacuum are available for sites located 5,000 feet or more above sea level
Greiner Bio-One VACUETTEŽ Blood Collection Tubes, 3mL, 9NC Coagulation Sodium Citrate 3.2%, 13 x 75mm, Blue Safety Cap, Black Ring, Sandwich Tube, Non-Ridged, Sterile (50/Rack)  [ MS0103-454334 ]
Price: $10.65
Quantity:
  
VACUETTE® Blood Collection Tubes; Additive: CAT Serum Clot Activator; Volume: 6mL: Size: 13 x 100mm; Cap Style: Safety; Cap Color: Red; Ring Color: Black; Tube Type: Non-Ridged; Sterility: Sterile; Quantity: 50/Rack

  • VACUETTE® tubes are used to collect, transport and process blood for testing serum, plasma or whole blood in the clinical laboratory
  • VACUETTE® Serum Tubes are coated with micronized silica particles which activate clotting when tubes are gently inverted
  • VACUETTE® No Additive Tubes and VACUETTE® Serum Clot Activator Tubes may be used for routine immunohematology testing i.e., red cell grouping, Rh typing and antibody screening
  • VACUETTE® No Additive Tubes and VACUETTE® Serum Clot Activator Tubes may be used for viral marker testing in screening and clinical laboratories
Greiner Bio-One VACUETTEŽ Blood Collection Tubes, 6mL, CAT Serum Clot Activator, 13 x 100mm, Red Safety Cap, Black Ring, Non-Ridged, Sterile (50/Rack)  [ MS0102-45689 ]
Price: $11.99
Quantity:
  
VACUETTE® Blood Collection Tubes; Additive: Serum Separator Clot Activator; Volume: 8mL: Size: 16 x 100mm; Cap Style: Safety; Cap Color: Red; Ring Color: Yellow; Tube Type: Non-Ridged; Sterility: Sterile; Quantity: 50/Rack

  • VACUETTE® tubes are used to collect, transport and process blood for testing serum, plasma or whole blood in the clinical laboratory
  • VACUETTE® Serum Clot Activator Tubes with Gel contain a barrier gel that is present in the bottom of the tube. The specific gravity of this material lies between the blood clot and the serum. During centrifugation, the barrier gel moves upward to the serum - clot interface, where it forms a stable barrier, separating the serum from fibrin and cells. Serum may be aspirated directly from the collection tube, which eliminates the need for transfer to another container. For specific parameter stability, refer to the recommendations of the assay and/or instrument manufacturer and/or specific CLSI documents (i.e., guidelines, standards).
  • VACUETTE® Serum Clot Activator with Gel Tubes may be used for therapeutic drug monitoring (TDM) testing.
Greiner Bio-One VACUETTEŽ Blood Collection Tubes, 8mL, CAT Serum Separator Clot Activator, 16 x 100mm, Red Safety Cap, Yellow Ring, Non-Ridged, Sterile (50/Rack)  [ MS0100-455071P ]
Price: $14.65
Quantity:
  
Sort By: